Fire Doors

Home » Fire Doors

Tower Fire delivers BAFE-accredited, RRFSO-compliant assessments and fire safety consultancy. Our team brings over 30 years of professional fire service experience. Request your free quote today.

Speak to an expert

Fire Doors:
Supply, Installation, and Inspection from Tower Fire

Tower Fire provides expert fire door installation, supply, and inspection services for businesses, landlords, and organisations across the UK. Every doorset we supply is specified for the correct fire resistance rating and building type. Every installation is carried out by qualified engineers to BS 8214 and documented with full certification. Every inspection is conducted by a team with direct fire safety experience who understand what a failing fire door looks like in practice, not just on a checklist.

Under the Regulatory Reform (Fire Safety) Order 2005, the responsible person must ensure fire doors are maintained in effective working order at all times. A fire door that does not close fully, has deteriorated seals, or has been wedged open is not a fire door. It is a gap in your building’s compartmentation, and when a fire occurs, that gap can cost lives. Correct fire door installation and regular inspection are not optional extras. They are a legal duty.

Fire Doors: Supply, Installation, and Inspection from Tower Fire
What Is a Fire Door?

What Is a Fire Door?

A fire door is a complete fire-resisting doorset: the frame, door leaf, intumescent seals, smoke seals, glazing, hinges, self-closing mechanism, and all associated hardware must all be tested and certified as a complete system. Each component must perform together during a fire for the door to provide its rated protection. Replacing one component with an uncertified alternative, or installing a certified door in an uncertified frame, can invalidate the entire doorset.

In the UK, fire doors are rated by their fire resistance period. An FD30 door provides 30 minutes of fire and heat resistance; an FD60 provides 60 minutes. The S suffix, as in FD30S or FD60S, indicates that cold smoke seals are incorporated, providing protection against smoke spread before temperatures reach the level that activates the intumescent seals. The correct rating for each location is determined by the building’s fire strategy and the fire risk assessment.

Legal Requirements for Fire Doors in the UK

Fire door compliance obligations in the UK are set by a combination of primary legislation and British Standards. The key requirements are:

  • RRFSO 2005: the responsible person must ensure fire doors are maintained in effective working order. Intact seals, a functioning self-closer, and correct gap tolerances are the minimum required standard
  • Fire Safety Act 2021: clarified that the RRFSO applies to the structure, external walls, and flat entrance doors of multi-occupied residential buildings
  • Fire Safety (England) Regulations 2022: buildings with storeys over 11 metres must carry out quarterly checks on fire doors in communal areas; all multi-occupied residential buildings must carry out annual checks on flat entrance doors
  • BS 8214: the British Standard for fire door assemblies covering specification, installation, and maintenance. The benchmark used by fire risk assessors, building control officers, and inspection specialists

Our Fire Door Installation and Inspection Service

Tower Fire provides a complete fire door installation UK and inspection service from initial fire door survey UK and specification through to ongoing maintenance and certification.

Fire Door Maintenance:

What Gets Checked

Fire door maintenance requires a consistent, documented inspection programme. A professional inspection assesses the following on every doorset:

Why Choose Tower Fire for Evacuation Training?

Why Choose Tower Fire for Fire Door Installation?

Tower Fire’s approach to fire door installation and inspection is grounded in genuine fire safety expertise. Our team has responded to fires in real buildings and understands what happens when a fire door fails to perform. That operational knowledge makes our inspections more thorough and our installation standards more exacting than those of a general contractor.
  • BS 8214-compliant installation with full certification for every doorset
  • Firefighter-led inspection programme with direct understanding of fire door failure in real emergencies
  • Complete service: supply, installation, inspection, maintenance, and remedial works under one contract
  • Nationwide coverage across all sectors and building types
FIRE SAFETY FAQ
Still have questions? Send us an email and we’ll get
back to you as soon as possible!

Send Email

FIRE SAFETY FAQ

Industry best practice recommends six-monthly professional inspections for most buildings. Under the Fire Safety (England) Regulations 2022, buildings with storeys over 11 metres must carry out quarterly checks on communal fire doors. High-risk environments such as care homes and hospitals may require more frequent inspection.

FD30 provides 30 minutes of fire resistance; FD60 provides 60 minutes. The correct rating for each location is determined by the building’s fire strategy and fire risk assessment. The S suffix indicates cold smoke seals are fitted.

Yes. Where the door leaf and frame remain structurally sound and the doorset is certified, Tower Fire can replace seals, closers, and hardware to restore compliance without full doorset replacement.

Under the RRFSO 2005, the responsible person, typically the employer, building owner, or appointed facilities manager, must ensure fire doors are maintained in effective working order. This duty cannot be transferred but the practical work can be carried out by a contractor.