P50 Fire Extinguisher

Home » P50 Fire Extinguisher

The Low-Maintenance, Long-Life Solution for UK Businesses

Get a P50 Quote

A smarter way to manage fire safety compliance

Managing fire safety compliance shouldn’t mean booking an engineer visit every twelve months.

The P50 fire extinguisher changes that. A revolutionary composite fire extinguisher designed to last 20 years, require no third-party annual servicing, and keep your premises covered across multiple fire classes.

At Tower Fire, we supply, install, and commission the full P50 range for businesses, landlords, and facilities teams across the UK.

Agent holding a fire extinguisher

What is a P50 fire extinguisher?

The P50 fire extinguisher is built differently from a standard unit. Its inner bottle is constructed from High-Density Polyethylene and wrapped in Aramid fibre — the same material found in Kevlar bulletproof vests. The result is an extinguisher that is genuinely robust yet noticeably lighter than a traditional steel equivalent. It also exceeds standard pressure requirements, with a burst pressure test result of over 70 bar against the 55 bar minimum.

Because the body is not steel, it will not rust or corrode over time. That makes it equally reliable in an office, a coastal warehouse, or an outdoor setting. The head cap includes dual magnetic gauges so pressure can be checked quickly and without any tools during the annual visual inspection.

Key Benefits of Choosing the P50 Composite Extinguisher

The P50 fire extinguisher is not just another extinguisher. It represents a fundamentally different approach to fire safety management. Here is what makes it the preferred choice for property managers, duty holders, and multi-site operators:

No annual servicing required The P50 is a true service-free fire extinguisher. You can carry out simple in-house visual inspections annually—no engineer visits needed.
Hourglass
20-year
lifespan
Traditional extinguishers typically last 10–12 years. The P50 doubles that, reducing replacement frequency and lifecycle costs.
Reliability
Corrosion-resistant design Ideal for both indoor and outdoor environments, including harsh or exposed locations such as coastal sites, warehouses, and industrial settings.
Fire Extinguisher
Multi-class fire coverage Many P50 models
cover multiple fire classes (A, B, C, F and electrical), meaning fewer units are required across your site.
Eco-friendly
PFAS-free foam options With increasing environmental regulations, P50 ECO foam models are PFAS-free, helping you stay compliant with the July 2025 PFOA ban.
ISO Standard
Lightweight and easy to handle Despite its strength, the composite design makes it easier for staff to handle and operate in an emergency.

P50 compliance

Does it meet UK fire safety standards?

YES — the P50 fire extinguisher is fully compliant with UK and European standards. It carries key certifications including BSI Kitemark, UKCA, EN3, PED, and MED.

Under BS 5306-3, it can be maintained through a competent person inspection model, allowing trained staff to complete annual checks in-house. It is widely accepted by fire risk assessors, the HSE, insurers, and enforcing authorities, making it a fully compliant fire safety solution when properly installed and commissioned.

Who is the P50 best suited for?

The P50 suits any organisation looking to simplify fire extinguisher management — but it delivers the greatest value for:

Facilities managers and multi-site operators who want a consistent, predictable compliance routine across all properties.

Schools, academies, and universities where minimising contractor disruption is a priority.

Landlords and HMO operators who require straightforward, auditable maintenance records.

Warehouses, light industrial sites, and retail units requiring robust coverage across varied fire risks.

Remote or restricted-access sites where scheduling annual engineer visits is genuinely difficult.

P50 vs traditional steel fire extinguishers

When comparing the P50 fire extinguisher cost against traditional steel units, the difference becomes clear over time.

1
Cost savings

Over 10 years, organisations can save 50%+ thanks to no servicing fees, fewer replacements, and reduced admin.

2
Maintenance

Steel: Annual servicing and testing required
P50: Simple in-house visual check once a year

3
Compliance

Easier record-keeping with quick, self-managed inspection logs—no external engineers needed.

The upfront cost of a P50 composite extinguisher is higher than a standard steel unit. However, when total cost of ownership is calculated over a 10-year period — accounting for annual servicing, five-year discharge and refill cycles, and replacement units — organisations routinely save over 50 per cent by switching to P50. Factor in the reduction in contractor scheduling, compliance paperwork, and potential downtime, and the financial case becomes clear.

Steel extinguishers remain appropriate for smaller sites or those with existing service contracts. For portfolio-scale operations, the P50 is the more cost-effective and operationally straightforward choice.

The P50 range available from Tower Fire

One of the biggest advantages of the service-free fire extinguisher model is the simplicity of maintenance.

POWDER

2kg, 6kg, 9kg
Covers Class A, B, C fires and electrical risk

FOAM

6L, 9L
Suitable for Class A, B fires and electrical equipment

WATER MIST

2L, 6L
Ideal for Class A fires and safe for use on electrical equipment

WET CHEMICAL

6L
Designed for commercial kitchens and cooking oil fires

AVD

6L
Specifically developed for modern battery risks

enquire  NOW

Our team will specify the correct type, rating, and quantity for your premises based on your fire risk assessment.

How to maintain a P50 extinguisher

One of the biggest advantages of the service-free fire extinguisher model is the simplicity of maintenance.

One of the biggest advantages of the service-free fire extinguisher model is the simplicity of maintenance.

1
Visually checking the gauge reads in the green zone
2
Removing the base magnet and confirming the magnetic gauge needle moves freely
3
Checking the safety pin and tamper tag are intact
4
Confirming the colour date stud is within its valid period
5
Checking the extinguisher is free from damage, clean, and in its designated location
6
Signing and dating the inspection record on the rear of the unit

Results must also be logged in your fire safety logbook. A free app (iOS and Android) is available to guide you through the process and store digital records.

FIRE SAFETY FAQ
Still have questions? Send us an email and we’ll get
back to you as soon as possible!

Send Email

FIRE SAFETY FAQ

No. It requires only a simple annual visual inspection carried out by a competent person within your own team. No third-party engineer is needed for 10 years.

20 years. After the first 10 years, the unit can be returned to the factory for refurbishment and used for a further decade.

Yes. The P50 holds BSI Kitemark certification and meets UKCA, EN3, PED, and MED standards. It is accepted by the HSE, fire authorities, risk assessors, and insurers across the UK.

Depending on the model, it covers Class A, B, C, and F fires as well as live electrical equipment up to 1,000V. In many cases, one P50 unit can replace two or more traditional extinguishers on the same site.

It is lighter, corrosion resistant, and built to last twice as long. It removes the need for annual engineer visits and the five-year discharge cycle. Most organisations save over 50 per cent in total costs over a 10-year period.

Yes. It is widely used in HMOs, blocks of flats, and managed residential properties, making it a practical choice for landlords and property managers maintaining compliance across multiple units.